Explanation + your calculation

What does an energy performance certificate mean? A1–G classes

Enter data from the certificate, not from the invoice. Displaying the class and comparing two buildings shows why less kWh per square meter does not necessarily mean less total heat.

Class A1–G here ranks the annual heating energy required per conditioned floor area on the calculation report. It is not a seismic safety class, final bill, or label of actual household consumption.

My calculation ↓See example

Explain my data

Interactive input is not yet available. Reopen page.

The calculation is local. Inputs are not sent to the server. An empty field does not automatically become 0.

Required, delivered, or primary energy?

The same certificate contains several energy indicators. The calculation on this page uses only the specific annual one required heat for heating on the accounting certificate. Delivered energy, primary energy, or kWh from the bill must not be automatically placed on the same scale. Therefore, if the wrong indicator is selected, we do not show the class.

In regulation 4/2023, the meaning of indicators and classification are described in Articles 5 and 6. For comparison, also transcribe the building designation or part of the building, the covered area, and the document date. The number for the entire block is not automatically the number for the apartment in the listing. The tool does not check the register and does not confirm the validity or authenticity of the document.

The standardized area according to the specified methodology is the conditioned area Ause. Sales area including balcony, garage, or other space may mean a different scope. If the scope is unclear, stop the comparison and request clarification from the issuer instead of using a larger number from the listing.

Scale of classes A1–G

The class boundary is included in the lower interval: the value 60 is C, the value above 60 belongs to D up to and including 105. The tool first sorts the raw entered number and only then rounds it for display. Colors assist in reading intervals, not a comprehensive property evaluation.

  1. A10–10 kWh/(m²·year)
  2. A2above 10 up to 15 kWh/(m²·year)
  3. B1above 15 up to 25 kWh/(m²·year)
  4. B2above 25 to 35 kWh/(m²·year)
  5. Cabove 35 to 60 kWh/(m²·year)
  6. Dabove 60 to 105 kWh/(m²·year)
  7. Eabove 105 up to 150 kWh/(m²·year)
  8. Fabove 150 to 210 kWh/(m²·year)
  9. Gabove 210 kWh/(m²·year)

This scale is intended to interpret the specified Slovenian indicator according to regulation 4/2023. Do not use it for foreign certificates, other indicators, or different methodologies. In case of regulation changes or unclear markings, check the current document and issuer.

From kWh per m² to annual heat

Calculated annual heat = indicator in kWh/(m²·year) × its conditioned area in m². If the area is missing, you can still read the class, but do not invent annual heat values. For the second building, we need an indicator and area to avoid mixing data from different certificates.

This multiplication does not include energy price, boiler efficiency, seasonal coefficient of heat pump, domestic hot water, or actual living patterns. Therefore, annual heat is not called annual electricity consumption and is not multiplied directly by the tariff as if it were a bill.

In the case study, the larger building has a better indicator per m² but a higher calculated annual heat demand than the smaller one. This is why it makes sense to first compare intensity and then the total scope, rather than selecting a winner based solely on the letter.

What to bring to the viewing?

Request a certificate that corresponds to the purchase subject and an explanation of the recommended measures. Separately collect invoices for the same period, data on actual room usage, and a description of the heating system. The recommendation on the certificate is not yet an offer to carry out the renovation.

Include the document and open questions in the dossier →. For the cost scenario, first define the same required heat for all systems, then use heating comparison →. If you want to compare actual bills, a more suitable option is overview of regular expenses →.

Fictitious case study

The example explains the method; it is not a price list, bank offer, or description of a specific building. You can replace it with your own data in the calculation.

Calculated case study
AssumptionResult of the same model
First building60 × 120 m² = 7200 kWh heat; class C
Other building75 × 90 m² = 6750 kWh heat; class D

Source, scope, and privacy

Regulation, Official Gazette of the RS 4/2023, Articles 5 and 6.. Source of explanation reviewed . Calculation and explanation: PreveriDom. We are not a bank, energy certificate issuer, or designer. Entries are not verified against personal records.

The input and report are created on your device. The file JSON preserves fields for continuation; HTML is a readable snapshot. We do not index private results or generate addresses for every combination of inputs. How we handle data · Methodology · About the project.

Your practical plan

Class is not the same as heating cost

Read the correct indicator for the type of certificate and check what is not included in the calculation.

Questions for the next step

  1. Did you use the correct indicator and area from the certificate?
  2. Does the building have data on actual consumption over several years?

The energy certificate describes the prescribed method; the result is NOT a guarantee of the bill.

Check before decision

Marked 0 of 3 tasks

  1. Check the class
  2. Heating cost
  3. Total budget

Designations are only your temporary list, not a confirmation or evaluation of the property. They reset when refreshing or changing the page.