Standalone tool for your property

Solar potential by address and PVGIS output

Official JRC PVGIS model for the selected point, twelve months of production and a separate financial scenario with your own prices. No promise of savings or contractor offer.

Where and how will the panels be installed?

Interactive input is not yet available. Reopen page.

1 · Location

First select the correct point

The address is processed by OpenStreetMap Nominatim. No personal names or confidential data.

2 · Power and coordinates

Calculation basis

3 · Layout

Tilt and direction of panels

Advanced: system losses

Change only if you have a better assumption for the specific system.

Primarily, our server sends only coordinates and technical setup to JRC. If the server path to JRC fails due to transport or 5xx outage, the browser can send the same technical data directly to the official PVGIS 6. Fixed crystalline panels, ventilated mounting, terrain from the model. Data processing

What the model tells — and what it does not see on your roof

Explanation content
  1. Power, tilt, and orientation
  2. Losses and shading
  3. Production is not financial return
  4. What to check before ordering
  5. How we calculate the financial scenario
  6. Source, version, and period
  7. Next related questions

The annual figure is only the beginning. When planning a power plant, also compare the months in which you need electricity. Winter consumption for heating and summer production do not coincide in time; therefore, a large annual total does not prove that the house will be self-sufficient. The tool shows average modeled production, not future weather forecasts.

Power, tilt, and orientation

Nominal power in kWp is composed from the power of panels in the technical offer. The tilt is measured from the horizontal plane. Orientation means the side of the sky the panels face; by convention PVGIS is south 0°, east −90°, and west 90°. Treat east and west roof sides as two separate installations, not as a southern average.

Losses and shading

Entered system losses are an assumption for the system. The model uses terrain and elevation horizon when confirmed by the source response. Nearby trees, chimney, neighbor’s building, and dirt are not checked by photo inspection. For roof installation, the contractor should verify ventilation and actual losses.

Production is not financial return

The avoided variable cost applies only to electricity you consume directly and to costs that actually decrease with lower supply. Use your contractual amount for energy fed back. Do not count fixed invoice items as automatic savings.

What to check before ordering

Check the load-bearing capacity and condition of the roof, orientation of individual roofs, local shading, connection possibilities, and intervention regimes separately. The data on heritage or other protected areas is not replaced by the production model. It is sensible to compare written offers under the same assumptions.

How we calculate the financial scenario

Annual energy is divided into the directly consumed share and the delivered share. The first is multiplied by the avoided variable price, the second by the delivery price, and the entered annual costs are subtracted. The simple payback period is the investment divided by the positive annual net effect. It does not include the time value of money, equipment replacement, degradation, financing, battery, or subsidy. If there is no net effect, the payback period is not shown as a meaningful number.

Source, version, and period

The primary calculation uses the documented server API PVGIS 5.3 (PVcalc, SARAH3). If this official JRC endpoint fails after two limited server attempts due to transport or 5xx outage, the browser directly calls the official PVGIS 6 performance API on a separate JRC host with SARAH-3 and completed year 2024. Hard 4xx, invalid JSON, or content-mismatched responses do not trigger a fallback result. The result always shows the actual source and period. For multi-year 5.3 models, we show interannual variability; for one-year PVGIS 6 fallback models, we do not present it as an interannual estimate. Successful server responses can be cached for up to six hours; direct PVGIS 6 responses are not stored in shared cache. Retrieval time is not the model creation date.

PVGIS 5.3 API ↗ · PVGIS 6 API ↗ · PVGIS manual and terms of use ↗. Results are used with attribution to the European Commission and JRC; PreveriDom is not an official JRC portal.

Next related questions

Check before intervention Cultural Heritage Context, prepare document file and include the investment in total property budget. To send the result, save a summary containing input parameters, source, and limitations.

Next part of the same decision

Data on municipality, production, financing, and documents do not replace spatial or expert review of a specific property.

Check the specific location →Nearby constructions →Overview of all tools →
Your practical plan

From sun model to feasible roof

Modeled production is only the first part of the project. Geometry, shading, energy use, and connection are separate issues.

Questions for the next step

  1. Does the roof have enough usable surface and adequate load-bearing capacity?
  2. Does production match the timing of your energy consumption?

PVGIS model is not a project, connection consent, or guaranteed financial return.

Check before decision

Marked 0 of 3 tasks

  1. Model PVGIS
  2. Panel layout
  3. Energy cost

Designations are only your temporary list, not a confirmation or evaluation of the property. They reset when refreshing or changing the page.

Next specific question