First the same heat, then price comparison
Explanation content
- Heat pump
- Fuel Boiler
- Direct electricity
- Annual fixed items
- Formulas you can verify
- What does the test −20 % and +20 % mean?
- Important calculation limit
- Sources and your next step
- Private storage without uploading documents
A kilowatt-hour of electricity and a kilowatt-hour of delivered heat are not the same input. To ensure the comparison does not favor a system just because it has a smaller load, all selected systems cover the same entered annual amount of heat. The tool does not infer this data from the address, surface area, or the house's year of construction.
Heat pump
Required electricity is calculated as delivered heat divided by the input seasonal heat/electricity ratio. The European Commission SCOP describes it as seasonal heating efficiency. For your scenario, you need data from a comparable climate and operating conditions. Single COP and seasonal data are not interchangeable.
Fuel Boiler
Required fuel energy is calculated from heat and seasonal efficiency. When using price per kilogram, liter, or ton, you must also enter the energy content of that specific unit. We do not guess how much energy the purchased fuel contains. The data on energy content and efficiency must use the same reference basis.
Direct electricity
The calculated ratio is 1 kWh electricity per 1 kWh heat at the selected calculation boundary. This does not mean the house’s heat losses disappear, nor does it prove the system is technically suitable. The heat demand is still determined by the building or your comparable input assumption.
Annual fixed items
Multiply the amount of energy by your variable price. Then add annual fixed charges and service. Do not double-count consumption already included in them. If there are no fixed expenses in the scenario, enter 0; an empty field does not mean they have been checked or assessed as zero.
Formulas you can verify
An empty initial deposit remains unknown. In that case, we still show energy expenses, not a fictitious payback period. If there is no positive annual saving, the payback period is not shown as a meaningful figure. If the deposit is lower and the annual expense smaller, we describe this directly, without negative “years to payback.”
What does the test −20 % and +20 % mean?
We only change the annual heat demand. The fuel price, seasonal efficiency, and annual fixed costs remain the same. The table shows the sensitivity of your budget, not a forecast of winter, future tariffs, or actual performance in frost. For a specific device, efficiency may also change with conditions.
Important calculation limit
For all systems, compare the same space heating and the same inclusion of sanitary water. Consumption of auxiliary heaters, pumps, and standby should be captured in comparable seasonal ratios or cost assumptions; do not count it twice. Seasonal efficiency percentages on the energy label are not automatically COP or SCOP. The tool does not size the device, calculate required power, or confirm radiator suitability.
The comparison does not include subsidies, financing, degradation, future prices, major replacements, or residual value. For investment decisions, verify documentation and comparable offers; a longer calculated payback period is not proof of an equally long lifespan.
Sources and your next step
Basic definitions: European Commission – seasonal efficiency SCOP and US Department of Energy – seasonal boiler efficiency. Sources are not used as a Slovenian price list, subsidy list, or certification for your device. Methodological definitions reviewed by 3. 10. 2026.
Download annual scenario to living expenses, manage actual offers in offer comparison, for panel installation use solar power plant model. Annual solar production is not automatically deducted from heating: the time of energy generation and consumption are not the same.
Private storage without uploading documents
All calculations are performed on your device. The tool does not call an API or send entered amounts. Export HTML for reading or JSON for later editing. When reopening, JSON checks the format and allowed inputs and recalculates the result. Input is not saved to a public link, personal account, or persistent browser storage.